BPVDJ - M18 GAS FILTER,5-19-2350
- MSDS: BPVDJ
- Manufacturer: INNOVISION INC
- Product Name: M18 GAS FILTER,5-19-2350
- National Stock Number: 4240-00-828-3952
Product Identification
Product ID:M18 GAS FILTER,5-19-2350
MSDS Date:03/31/1992
FSC:4240
NIIN:00-828-3952
MSDS Number: BPVDJ
Responsible Party
DEER PARK, NY 11729
US
Emergency Phone: 516-586-0303 (8AM-5PM M-F)
Info Phone: 516-586-0303 (8AM-5PM M-F)
Cage: 0F6F7
Contractor
Telephone: 516-586-0303 (8AM-5PM M-F)
Cage: 0F6F7
Ingredients
CARBON IMPREGNATED WITH COPPER,CHROMIUM AND SILVER.OSHA PEL
CAS: 7440-44-0
RTECS: FF5250100
Fraction By Weight: 52%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 2 MG/M3 TDUST; 9293
COPPER (SARA III).OSHA PEL AND ACGIH TLV 1 MG/M3 DUST.
CAS: 7440-50-8
RTECS: GL5325000
OSHA PEL 0.1 MG/M3 FUME
ACGIH TLV: 0.2 MG/M3 FUME
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
CHROMIUM (SARA III)
CAS: 7440-47-3
RTECS: GB4200000
OSHA PEL 1 MG/M3
ACGIH TLV: 0.5 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
SILVER (SARA III)
CAS: 7440-22-4
RTECS: VW3500000
OSHA PEL 0.01 MG/M3
ACGIH TLV: 0.1 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
LD50 LC50 Mixture:NOT KNOWN
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THE M18 FILTER ITSELF IS
NONTOXIC,HOWEVER LONG TERM EXPOSURE TO ASC CARBON DUST OR FINES MAY
BE HAZARDOUS DUE TO THE PRESENCE OF CHROMIUM TRIOXIDE,WHICH MAY
PRESENT A CARCINOGENIC RISK.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:NOT KNOWN
Medical Cond Aggravated by Exposure:NOT KNOWN
First Aid
First Aid:EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES .SKIN:EXPOSURE TO ASC CARBON DUST SHOULD BE WASHED AWAY
WITH WATER.
Fire Fighting
Flash Point:NOT KNOWN
Lower Limits:NOT KNOWN
Upper Limits:NOT KNOWN
Extinguishing Media:IF INVOLVED IN FIRE,FLOOD WITH PLENTY OF WATER.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS (SCBA)
AND FULL TURNOUT GEAR .
Unusual Fire/Explosion Hazard:IF ASC CARBON INSIDE THE FILTER COMES IN
CONTACT WITH STRONG OXIDIZERS SUCH AS OZONE,LIQUID
OXYGEN,CHLORINE,PERMANGANATE,ETC.,FIRE COULD RESULT.
Accidental Release
Spill Release Procedures:IF FILTER IS DAMAGED AND ASC CARBON IS
SPILLED,SWEEP UP CARBON AND DISCARD IN REFUSE CONTAINER.IF
RELEASED,REPORT IN ACCORDANCE WITH LOCAL,STATE,AND FEDERAL
REGULATIONS.
Neutralizing Agent:NOT KNOWN
Handling
Handling and Storage Precautions:NO UNUSUAL PRECAUTIONS ARE NEEDED FOR
STORAGE AND HANDLING.
Other Precautions:USED FILTERS SHOULD NOT BE IMMERSED IN WATER IN SMALL
CONFINED SPACES,SINCE WET ASC CARBON REMOVES OXYGEN FROM AIR.
Exposure Controls
Respiratory Protection:A NIOSH APPROVED PARTICULATE FILTER RESPIRATOR
IS RECOMMENDED IF EXCESSIVE DUST IS GENERATED.
Ventilation:PARTICULATE FILTRATION OF EXHAUST IS RECOMMENDED.
Protective Gloves:NOT REQUIRED
Eye Protection:NOT REQUIRED
Other Protective Equipment:NOT REQUIRED
Work Hygienic Practices:DUST FROM ASC CARBON SHOULD NOT BE INHALED OR
INGESTED & SHOULD BE REMOVED FROM SKIN BY WASHING WITH SOAP AND
WATER.
Supplemental Safety and Health
WASTE DISP:AND MAY BE SUBJECT TO REPORTABLE QUANTITY RULES IF WASTE IS
SPILLED.
Chemical Properties
Boiling Pt:B.P. Text:NOT KNOWN
Melt/Freeze Pt:M.P/F.P Text:NOT KNOWN
Decomp Temp:Decomp Text:NOT KNOWN
Vapor Pres:NOT KNOWN
Vapor Density:NOT KNOWN
Spec Gravity:NOT KNOWN
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WHITE PAINTED METAL CANISTER ASSEMBLY.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS SUCH AS OZONE,LIQUID OXYGEN,CHLORINE,PERMANGANATE,ETC.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:CARBON MONOXIDE MAY BE GENERATED BY
BURNING ASC CARBON INSIDE M18 FILTERS.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE,AND LOCAL REGULATIONS.COORDINATE WITH SUPPORTING
INSTALLATION AND/OR MACOM ENVIRONMENTAL OFFICE PRIOR TO DISPOSAL
.WASTE MATERIAL SHOULD BE MANI FESTED AS D007 FOR EXTRACTABLE
CHROMIUM(SUP DATA)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.